This allows users to create an anchor point on the other side of the sloping roof.
Pitched roof edge protection.
Where work is of short duration tasks measured in minutes properly secured ladders to access the roof and proper roof.
A low sloped roof has a slope less than or equal to 4 inches of vertical rise for every 12 inches horizontal length.
Low slope roof 4 12 slope or less 29 cfr 1926 501 b 10.
The european norm establishes three classes of edge protection system.
Rss is a complete edge protection system for both flat and sloping roofs the lightweight aluminium fence can be hooked onto the roof edge and is supported against the façade by a stanchion.
Contrary to popular belief an anchor point does not necessarily have to be situated above the work location.
The rss edge protection system causes no damage to the façade and does not stand on the ground.
Each employee on a walking working surface horizontal and vertical surface with an unprotected side or edge which is 6 feet 1 8 m or more above a lower level shall be protected from falling by the use of guardrail systems safety net systems or personal fall arrest systems.
Steep roof above 4 12 slope 29 cfr 1926 501 b 11.
This edge protection needs to be strong enough to withstand a person falling against it and the longer the slope and the steeper the pitch this stronger the edge protection needs to be.
Class b 10 30 degree roof pitch.
Sloping roofs require scaffolding to prevent people or materials falling from the edge.
Osha 29 cfr 1926 501 b 10 allows protection from falling via the use of guardrail systems safety net systems or personal fall arrest systems but also allows more options.
Employers are to ensure that each employee is protected from falling by using fall protection systems such as guardrails safety net system fall restraint or fall arrest systems.
Employers must provide the right equipment employers must provide fall protection and the right equipment for the.
By using a throwing line for work on sloping roofs a rope can be pulled over the roof.
Know the pitch of the roof and follow the appropriate standard.
What about low sloped roofs.
You must also fit edge protection to the eaves of any roof and on terraced properties to the rear as well as the front.
Unprotected sides and edges.
For roofs pitched over 35 degrees have a platform at the same level as the working surface or bring of the inside handrail and mesh guard a maximum of 100mm laterally from the leading edge gutter or slab edge roof pitch 25 35 degrees.
Class c 30 45 degree roof pitch.
Less than 6 feet from the roof edge.
All classes have a static load requirement and class b c also have a dynamic load applied representing someone rolling down the roof slope and making contact with the edge.